AXJ Axial Jet Fan
Axial jet fan series for directed air movement in car park and tunnel ventilation.
Product Features
- General
There are different model options in the range of 315–450 mm.
- General
It can be produced as double speed and reversible.
- General
The fan casing is made of galvanized sheet and integrated with a silencer.
- General
With aerofoil section and adjustable angle, the blades are produced by aluminium injection casting.
- General
For S1 normal ventilation it is suitable for continuous operation from -20°C to +55°C.
- General
For S2 fire mode, 200°C/2h, 300°C/2h and 400°C/2h options are available.
- General
Wire mesh on the suction side and a deflector on the discharge side are standard.
- General
The fan is certified according to EN 12101-3:2015.
- Motor
The 2/4-pole motor is IP55 protected, IE2/IE3 high efficiency, fully enclosed, with self-lubricating bearings and H insulation class.
- Motor
An external IP67 electrical junction box is provided outside the fan casing.
- Motor
It is 400V-50Hz as standard and suitable for use with a frequency converter.
Where is it used?
Model Technical Data
Nominal airflow alone is not a selection criterion. Verify the final model together with the required pressure and duty point in Fan Selection.
| Model | Nominal airflow | Voltage | Motor power | Speed | Current | Sound | Thrust |
|---|---|---|---|---|---|---|---|
| AXJ 31-2/4T | 4.800/2.400 m³/h | 400V-50Hz | 0,80/0,20 kW | 2840/1420 rpm | 2,08/0,60 A | 62/47 dB(A) | 36/9 N |
| AXJ 35-2/4T | 6.800/3.400 m³/h | 400V-50Hz | 1,10/0,25 kW | 2860/1430 rpm | 2,51/0,74 A | 65/49 dB(A) | 56/14 N |
| AXJ 40-2/4T | 9.600/4.800 m³/h | 400V-50Hz | 1,50/0,37 kW | 2860/1430 rpm | 3,78/1,25 A | 66/51 dB(A) | 76/19 N |
| AXJ 40-2/4T | 10.500/5.250 m³/h | 400V-50Hz | 2,20/0,55 kW | 2880/1440 rpm | 4,91/1,65 A | 68/53 dB(A) | 84/21 N |
Source: Vensis Fan Selection Suite. Product and motor configurations must be verified for the ordered model.
Frequently Asked Technical Questions
What is AXJ?
Axial jet fan series for directed airflow in car park and tunnel ventilation. Sub-models in this product family are listed on this page from the Vitlo product database.
How do I select the right model?
Along with the required airflow, system pressure, operating conditions and any special safety requirements must be defined. The duty point should then be verified in Fan Selection.
Why are the technical table and selection tool used together?
The product page provides clear technical context, while Fan Selection verifies the model and duty point.
Let’s select the right fan for your project.
Share airflow, pressure and application conditions; we will evaluate the appropriate series and model.